Customization: | Available |
---|---|
After-sales Service: | Video Mode |
Warranty: | One Year |
Still deciding? Get samples of US$ 2500/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Overview
The smart flowmeter is a kind of high-accuracy and high-reliability flow meter to measure flow volume of conductive liquid or serum in a closed sealing pipeline. Widely used in electric power plant, oil and gas industry, chemical industry, coal, metallurgy, mining, paper making, water supply and drainage, food and other industries.
Features
Ex-type instrument is used for relative Ex-proof environment.
Range selection parameters
Inner dia.(mm) | Flow range(m3/h) | Inner dia.(mm) | Flow range(m3/h) |
DN10 | 0.3~1.6 | DN300 | 300~1200 |
DN15 | 0.8~3.0 | DN350 | 400~1600 |
DN20 | 1.2~5.0 | DN400 | 500~2000 |
DN25 | 2.0~8.0 | DN450 | 600~2500 |
DN32 | 3.0~12 | DN500 | 800~3000 |
DN40 | 5.0~20 | DN600 | 1000~4000 |
DN50 | 8.0~40 | DN700 | 1600~5000 |
DN65 | 12~60 | DN800 | 2000~6000 |
DN80 | 20~120 | DN900 | 2000~8000 |
DN100 | 30~160 | DN1000 | 2500~10000 |
DN125 | 50~250 | DN1200 | 3000~12000 |
DN150 | 80~400 | DN1400 | 4000~16000 |
DN200 | 120~600 | DNH1600 | 5000~20000 |
DN250 | 200~800 |
Q: The new magnetic flap liquid level gauge can't show liquid level?
A: 1.check whether there is block in by pass pipe 2.check the the density of medium 3.check whether the float ball is stucked by float ball.
Q: The longest length of magnetic flap liquide level gauge?
A: the length is customized,but in order to be convenient for transport,if the length is over 6m,we recommend
Q: If the float ball is installed at the wrong opposite direction,what's the influence?
A: reading level will be higher than true level,usually higher by length of floatball-70mm
Q: What's installation details of magnetic flap liquid level gauge ?
A: 1.before installation,check specification with label plate. 2.There shouldn't magnetic field within 400m
Q: There is problem in output signal 4--20mA?
A: 1.Check working power supply 2.check wiring 3,check load resistance 4.verify measuring range,zero point
Q: what's specification we need to know before purchasing magnetic flap liquid level gauge?
A: medium density,working temperature,working pressure,material,flange center to center distance,flange standard,whether need 4--20mA output signal;whether need level alarm