Electromagnetic Flowmeter for Measuring Conductive Liquids

Product Details
Customization: Available
After-sales Service: Video Mode
Warranty: One Year
Still deciding? Get samples of US$ 2500/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
3180000 RMB
Management System Certification
ISO 9001
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
  • Electromagnetic Flowmeter for Measuring Conductive Liquids
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
HXLD
Accuracy
±0.2-0.5%
Main Application
Water, Wastewater
Size
DN100-500
Sensor
Plug-in
Application
Transportation
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Measurement Object
Closed Pipeline
Certification
GB, ISO
Transport Package
Standard Package
Specification
electromagnetic flowmeter
Trademark
HX OR AS required
Origin
Chongqing
HS Code
9026201090
Production Capacity
50000PCS/Y

Product Description

Product Description

 

1. Overview

Electromagnetic flowmeter design and manufacturing in line with the standard JB/T9248-2015 "electromagnetic flowmeter", is a measurement of conductive medium volume flow speed instrument, in the field monitoring display at the same time, can output the standard current signal, for recording, regulation, control use, automatic detection control, and can realize the signal long-distance transmission. Widely used in environmental protection, steel, petroleum, chemical, coal, metallurgy, minerals, paper, water supply and drainage, food, medicine and other industries in the flow measurement of conductive liquid. The structure of the instrument has a body type and a sub-body type.

2. Special points

No moving parts in the measuring tube, easy to maintain and manage; Free flow parts, no pressure loss;

★ The lowest electrical conductivity of the measured liquid is ≥20μS/cm. With various lining materials, it can be used to measure the flow of various acid, alkali, salt solution and mud, pulp, pulp and other media.

★ The measurement accuracy is not affected by the fluid density, viscosity, temperature, pressure and conductivity changes, the sensor induced voltage signal and the average flow rate is linear relationship, high measurement accuracy;

Low frequency rectangular wave excitation, not affected by power frequency and field interference, stable and reliable work;

★ Not affected by the direction of fluid, positive and negative can be accurate measurement;

★ LCD backlight display, online parameter modification, easy to operate;

★ Chinese and English display mode (optional);

★ Can record the forward total, reverse total and difference total;

★ It has the function of air control measurement and alarm, and can adapt to different fluid medium.

3. Measurement principle

Electromagnetic flowmeter is the use of Faraday's law of electromagnetic induction principle, that is, conductive objects in the magnetic field to cut the magnetic line of force motion, induction electromotive force in the conductor. Its induced electromotive force

E is: E=KBdV
 

Detailed Photos

 

Electromagnetic Flowmeter for Measuring Conductive Liquids

Product Parameters

Range selection parameters

Inner dia.(mm) Flow range(m3/h) Inner dia.(mm) Flow range(m3/h)
DN10 0.3~1.6 DN300 300~1200
DN15 0.8~3.0 DN350 400~1600
DN20 1.2~5.0 DN400 500~2000
DN25 2.0~8.0 DN450 600~2500
DN32 3.0~12 DN500 800~3000
DN40 5.0~20 DN600 1000~4000
DN50 8.0~40 DN700 1600~5000
DN65 12~60 DN800 2000~6000
DN80 20~120 DN900 2000~8000
DN100 30~160 DN1000 2500~10000
DN125 50~250 DN1200 3000~12000
DN150 80~400 DN1400 4000~16000
DN200 120~600 DNH1600 5000~20000
DN250 200~800    
Certifications

Electromagnetic Flowmeter for Measuring Conductive LiquidsElectromagnetic Flowmeter for Measuring Conductive Liquids

Company Profile

Electromagnetic Flowmeter for Measuring Conductive LiquidsElectromagnetic Flowmeter for Measuring Conductive Liquids

Our Advantages

Electromagnetic Flowmeter for Measuring Conductive Liquids

FAQ

 

1. How long will you reply me?
Normally in 1 hours, no more than 12 hours.

2. How can I get the quotation?
Please provide specification and application including sensing element, pressure range, thread connection, pressure type, medium, electronic connection, shell material etc. More details, more accurate quotation and earlier response.

3. Can I get sample? Contact with our staff online directly and they would check stock for you.

4. Can I visit your factory?
You are warmly welcomed, our factory is located at Beibei District, Chongqing, China.

5. Can we use our logo on the products?
Yes, we provide OEM/ODM service.

6. How long is your warranty period?
Warranty period from the date of acceptance of 12 months.

7. What is your terms of payment?
We could accept T/T, L/C, Western union, PayPal, etc.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier