Customization: | Available |
---|---|
After-sales Service: | Video Mode |
Warranty: | One Year |
Still deciding? Get samples of US$ 250/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Overview
The smart flowmeter is a kind of high-accuracy and high-reliability flow meter to measure flow volume of conductive liquid or serum in a closed sealing pipeline. Widely used in electric power plant, oil and gas industry, chemical industry, coal, metallurgy, mining, paper making, water supply and drainage, food and other industries.
Features
Inner dia.(mm) | Flow range(m3/h) | Inner dia.(mm) | Flow range(m3/h) |
DN10 | 0.3~1.6 | DN300 | 300~1200 |
DN15 | 0.8~3.0 | DN350 | 400~1600 |
DN20 | 1.2~5.0 | DN400 | 500~2000 |
DN25 | 2.0~8.0 | DN450 | 600~2500 |
DN32 | 3.0~12 | DN500 | 800~3000 |
DN40 | 5.0~20 | DN600 | 1000~4000 |
DN50 | 8.0~40 | DN700 | 1600~5000 |
DN65 | 12~60 | DN800 | 2000~6000 |
DN80 | 20~120 | DN900 | 2000~8000 |
DN100 | 30~160 | DN1000 | 2500~10000 |
DN125 | 50~250 | DN1200 | 3000~12000 |
DN150 | 80~400 | DN1400 | 4000~16000 |
DN200 | 120~600 | DNH1600 | 5000~20000 |
DN250 | 200~800 |
Q: The new magnetic flap liquid level gauge can't show liquid level?
A: 1.check whether there is block in by pass pipe 2.check the the density of medium 3.check whether the float ball is stucked by float ball.
Q: The longest length of magnetic flap liquide level gauge?
A: the length is customized,but in order to be convenient for transport,if the length is over 6m,we recommend
Q: If the float ball is installed at the wrong opposite direction,what's the influence?
A: reading level will be higher than true level,usually higher by length of floatball-70mm
Q: What's installation details of magnetic flap liquid level gauge ?
A: 1.before installation,check specification with label plate. 2.There shouldn't magnetic field within 400m
Q: There is problem in output signal 4--20mA?
A: 1.Check working power supply 2.check wiring 3,check load resistance 4.verify measuring range,zero point
Q: what's specification we need to know before purchasing magnetic flap liquid level gauge?
A: medium density,working temperature,working pressure,material,flange center to center distance,flange standard,whether need 4--20mA output signal;whether need level alarm